Power supply: |
Direct current |
Working voltage: |
8.2 Vdc (1Kohm) |
Sensing hole diameter (mm): |
12 |
Minimum detectable object (mm): |
Ø 1.2 x 2 |
Output type: |
Namur |
Max. switching frequency: |
600 ÷ 1000 Hz |
Repeatability (%Sn): |
<= 0.3 |
Current absorption at 8.2V: |
Target detected <= 1 mA - Target not detected >= 3 mA |
Led indicator: |
Present |
Operating temperature limits: |
-25 ÷ +60 °C |
Storage temperature limits: |
-30 ÷ +70 °C |
IP rating: |
IP 67 |
Housing material: |
Plastic |
Cable type: |
2x0.25 mm² PVC |
Weight: |
80 g |
Mechanical characteristics: |
SIA05 41x70x12 |
Connection type: |
Cable 3 m |
Explosive atmosphere type: |
Mixture Air/gas and/or Air/Dust |
Equipment category: |
1G / 1D |
Installation area: |
Gas: Zone 0, Zone 1 and Zone 2 - Dust: Zone 20, Zone 21 and Zone22 |
Protection method: |
Intrinsically safe |
Marking: |
Gas: II 1G Ex ia IIB T5 Ga - Dust: II 1D Ex ia IIIC T100°C Da IP66 -25< Ta |
Safety information: |
Connection to certified intrinsically safe circuits only with the following values : Uo <= 17 V , |
Conforming standard: |
EN60079-0, EN60079-11, EN60079-26 and EN60947-5-6 |
EC-tipe examination certificate - ATEX: |
IMQ 13 ATEX 019 |
Certificate of conformity (CoC) - IECEx: |
IECEx IMQ 13.0012X |